top of page
  • Pre-Orders with an Expected time of Delivery in 2 - 4 Weeks

    • Alkalinity
    • Calcium
    • Low Range and High Range Nitrate
    • Ultra Low Range Nitrite
    • Ultra Low Range Phosphate
    • pH

    All-In-One Testing with Precise Results for Reef Tanks
    The HI97105 Marine Master Photometer is a waterproof tester that combines accuracy and ease of use into one simple, portable design. Its advanced, lab-quality optical system ensures accurate readings while its user-friendly design and built-in tutorials make it perfect for marine scientists and aquarium hobbyists alike.

    • Precise and advanced LED optical system
    • No warm up time needed before taking a measurement
    • Waterproof and floating IP67 meter design
    • CAL Check validation and calibration
    • Consolidates testing needs into one unit
    • Includes auto-data logging features to easily record water testing results
    • On-screen tutorial mode guides users step-by-step through the measurement process
    • Option to select measurement location for better tracking consistency
    • Auto shut-off
    • Rugged carrying case included

     

    Testing Parameter

    Specifications

    Marine
    Alkalinity

    Range0.0 to 20.0 dkH
    0 to 357 ppm (as CaCO3)
    Resolution0.1 dkH
    Accuracy±0.3 dKH ±5 % of reading at 25 °C
    ±5 ppm ±5 % of reading at 25 °C
    MethodColorimetric Method - The reaction causes a distinctive range of colors from yellow to greenish blue to develop

    Marine
    Calcium

    Range200 to 600 ppm
    Resolution1 ppm
    Accuracy±6 % of reading at 25 °C
    MethodAdaptation of the Zincon Method

    Marine
    Nitrate

    Range0.00 to 5.00 ppm (as NO3¯)
    0.0 to 75.0 ppm (as NO3¯)
    Resolution0.01 ppm
    0.1 ppm
    Accuracy0 to 200 ppb (as NO2¯-N)
    MethodAdaptation of the Zincon Method
    Colorimetric Method The reaction between nitrate and the reagent causes a pink/violet tint in the sample.

    Marine
    Nitrite ULR

    Range0 to 200 ppb (as NO2¯-N)
    Resolution1 ppb
    Accuracy±10 ppb ±4 % of reading at 25 °C
    MethodAdaptation of the EPA Diazotization Method 354.1 - The reaction between nitrite and the reagent causes a pink tint in the sample.

    Marine
    pH

    Range6.3 to 8.6 pH
    Resolution0.1 pH
    Accuracy±0.2 pH of reading at 25 °C
    MethodColorimetric Adaptation of the Phenol Red Method

    Marine
    Phosphate LR

    Range0.00 to 0.90 ppm
    Resolution0.01 ppm
    Accuracy±0.02 ppm ±5 % of reading at 25 °C
    MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method - The reaction between phosphate and the reagent causes a blue tint in the sample.

    General

    Light SourceLight emitting diode
    Light DetectorSilicon photocell
    Bandpass Filter Bandwidth8 nm
    Bandpass Filter Wavelength Accuracy±1.0 nm
    Logging200 readings
    Power Supply1.5 V AA Alkaline (3 pcs.)
    Battery Life> 800 measurements (without backlight)
    Auto-offAfter 15 minutes of inactivity (30 minutes before a READ measurement)
    Environment0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable
    Dimensions142.5 x 102.5 x 50.5 mm (5.6" x 4.0" x 2.0")
    Weight380 g (13.4 oz.); with batteries

    Hanna Marine Master HI97105

    ₹49,999.00Price
      bottom of page